- Home
- รีเลย์
- รีเลย์ OMRON (Relay Omron)
- Solid State Relay Omron G3PE-235B-3N DC12-24
Solid State Relay Omron G3PE-235B-3N DC12-24
Solid State Relay Omron G3PE-235B-3N DC12-24
OMRON
กรุณาตรวจสอบสต็อกก่อนชำระเงินราคาปกติ
19,875.00 ฿
ราคาปกติ
ราคาโปรโมชัน
19,875.00 ฿
ราคาต่อหน่วย
/
ต่อ
รายละเอียด Solid State Relay Omron G3PE-235B-3N DC12-24
G3PE Series
Omron G3PE Series solid state relays with heat sinks for a wide range of applications.
Models also available with no zero cross
Compact with a slim profile
Improved surge dielectric strength for output circuits
Screw and DIN track mounting possible
RoHS compliant
Compact with a slim profile
Improved surge dielectric strength for output circuits
Screw and DIN track mounting possible
RoHS compliant
G3PE-235B-3N DC12-24 SSR – Compact 3-Phase Solid State Relay.
The G3PE SSR – Solid State Relay series have a slim compact design complete with built-in heat sinks. Solid state contactors for 3-phase heaters, reduced installation and available to DIN rail mount or screw mount. RoHS compliant with surge protection.
Features and Benefits of G3PE-235B-3N DC12-24 Compact SSR – Solid State Relay.
• Three-phase.
• Phototriac coupler.
• Yellow indicator.
• Rated input voltage 12 to 24 V dc.
• Zero cross function.
• DIN Rail Mounting available
• Applicable load 35 A, 100 to 240 V ac. (dependent upon the ambient temperature).
• 3 Poles.
• Built-in heat sink.
• Phototriac coupler.
• Yellow indicator.
• Rated input voltage 12 to 24 V dc.
• Zero cross function.
• DIN Rail Mounting available
• Applicable load 35 A, 100 to 240 V ac. (dependent upon the ambient temperature).
• 3 Poles.
• Built-in heat sink.
SSR – Solid State Relay Input Rating at 25°C.
• Operating voltage range 9.6 to 30 V dc.
• Rated input current 10 mA max. (24 V dc).
• Must operate voltage 9.6 V dc max.
• Must release voltage 1 V dc max.
• Rated input current 10 mA max. (24 V dc).
• Must operate voltage 9.6 V dc max.
• Must release voltage 1 V dc max.
SSR – Solid State Relay Output.
• Rated load voltage 100 to 240 V ac, 50 / 60 Hz.
• Load voltage range 75 to 264 V ac, 50 / 60 Hz.
• Applicable load current 35 A at 25°C. (dependent upon the ambient temperature).
• Load current minimum 0.2 A.
• Inrush current 440 A, 60 Hz, 1 cycle. Peak value.
• Resistive load 1.21 kW at 200 V ac.
• Load voltage range 75 to 264 V ac, 50 / 60 Hz.
• Applicable load current 35 A at 25°C. (dependent upon the ambient temperature).
• Load current minimum 0.2 A.
• Inrush current 440 A, 60 Hz, 1 cycle. Peak value.
• Resistive load 1.21 kW at 200 V ac.
Additional Features G3PE-235B-3N DC12-24 Compact SSR 3-Phase SSR – Solid State Relay.
• Operate and release time load power source cycle + 1 ms max.
• Output ON voltage drop 1.6 V (RMS) max.
• Leakage current 10 mA max at 200 v ac.
• Vibration resistance 10 to 55 to 10 Hz, 0.175 single amplitude, 0.33 mm double amplitude – DIN rail mounted.
• Vibration resistance 10 to 55 to 10 Hz, 0.375 single amplitude, 0.75 mm double amplitude – Screw mounted.
• Shock resistance destruction 294 m/s² DIN rail mounted.
• Operating temperature – ambient -30°C to 80°C, no icing or condensation.
• Relay weight 1.65 kg.
• Output ON voltage drop 1.6 V (RMS) max.
• Leakage current 10 mA max at 200 v ac.
• Vibration resistance 10 to 55 to 10 Hz, 0.175 single amplitude, 0.33 mm double amplitude – DIN rail mounted.
• Vibration resistance 10 to 55 to 10 Hz, 0.375 single amplitude, 0.75 mm double amplitude – Screw mounted.
• Shock resistance destruction 294 m/s² DIN rail mounted.
• Operating temperature – ambient -30°C to 80°C, no icing or condensation.
• Relay weight 1.65 kg.
What does Zero Cross Function mean in SSR in Solid State Relays?
Zero cross function will allow the relay to turn ON when the AC load power supply approaches 0 V suppressing any noise generated with a sudden load current increase. Zero cross function is effective across 2 types of noise, noise on power lines and noise emitted into open space.
Standards
UL508, CSA22.2 No.14, EN 60947-4-3.
Specification
คุณสมบัติ | Value |
Maximum Load Current | 35 A |
Mounting Type | DIN Rail |
Maximum Load Voltage | 264 V ac |
Minimum Load Voltage | 75 V ac |
Minimum Control Voltage | 9.6 V dc |
Maximum Control Voltage | 30 V dc |
Switching Type | Zero Cross |
Control Voltage Range | 9.6 → 30 V dc |
Minimum Load Current | 0.5 A |
Terminal Type | Screw |
Contact Configuration | 3P-NO |
Output Device | Phototriac Coupler |
Load Voltage Range | 75 → 264V ac |
Series | G3PE Three Phase |
Maximum Turn On Time | 1/2 cycle |
Dimensions | 80 x 155 x 140mm |
Depth | 155mm |
Operating Temperature Range | -30 → +80°C |
Length | 80mm |
Off State Leakage Current | 10 mA |
Height | 140mm |
Maximum Operating Temperature | +80°C |
Share
- การเลือกตัวเลือกจะส่งผลให้มีการรีเฟรชทั้งหน้า
- เปิดในหน้าต่างใหม่