รายละเอียด Solid State Relay Omron G3PA-430B-VD-2 DC12-24
DIN Rail Mount SSR's
Replaceable SSR power cartridge
DIN rail or surface mounting options
Finger protected terminals
LED input status indicator
Thermal overload indicator changes colour permanently to indicate possibility of a damaged power cartridge
Inputs may be ’commoned’ via integral linking terminals
Release Voltage 1 Vdc (Min)
Operating Temperature Range -30 to +80°C
DIN rail or surface mounting options
Finger protected terminals
LED input status indicator
Thermal overload indicator changes colour permanently to indicate possibility of a damaged power cartridge
Inputs may be ’commoned’ via integral linking terminals
Release Voltage 1 Vdc (Min)
Operating Temperature Range -30 to +80°C
Approvals
UL; CSA; VDE
G3PA-430B-VD-2 DC12-24 SSR – Solid State Relay with Replaceable Power Cartridge.
The design of the heat sink provides a smaller SSR – solid state relay with easily maintained replaceable element cartridges. The relays are applicable with 3-phase loads. The G3PA series of SSR – solid state relays can be DIN rail mounted or mounted using screws.
Features and Benefits of G3PA-430B-VD-2 DC12-24 SSR –Solid state relay.
• Phototriac coupler.
• Zero cross function.
• Indicator.
• Rated output load 20 A at 200 to 480 V ac.
• Rated input voltage 12 to 24 V dc.
• VD – certified UL, CSA, VDE.
• Zero cross function.
• Indicator.
• Rated output load 20 A at 200 to 480 V ac.
• Rated input voltage 12 to 24 V dc.
• VD – certified UL, CSA, VDE.
SSR – Solid state relay Input Rating at 25°C ambient.
• Operating voltage range 9.6 to 30 V dc.
• Input current impedance 7 mA max.
• Must operate voltage 9.2 V dc max.
• Must release voltage 1 V dc.
• Input current impedance 7 mA max.
• Must operate voltage 9.2 V dc max.
• Must release voltage 1 V dc.
SSR – Solid state relay Output.
• Rated load voltage 200 to 480 V ac, 50 / 60 Hz.
• Load voltage range 180 to 528 V ac, 50/ 60 Hz.
• Load current 0.5 to 30 A at 30°C.
• Inrush current 440 A, 60 Hz, 1 cycle.
• VDRM 1200 V.
• Load voltage range 180 to 528 V ac, 50/ 60 Hz.
• Load current 0.5 to 30 A at 30°C.
• Inrush current 440 A, 60 Hz, 1 cycle.
• VDRM 1200 V.
Additional Features G3PA-430B-VD-2 DC12-24 SSR – Solid State Relay.
• Operate and release time of load power source cycle + 1 ms max (DC models). 1 pf load power source cycle + 1 ms max (AC input).
• Output ON voltage drop 1.8 V (RMS) max.
• Leakage current 20 mA max at 480 V ac
• Vibration resistance – destruction – 10 to 55 to 10 Hz, 0.375 mm single amplitude mounted to a DIN rail.
• Shock resistance – destruction – 300 m/s² mounted to a DIN rail.
• Operating temperature – ambient - -30°C to 80°C. No icing or condensation.
• Screw terminal.
• Relay weight 410 g.
• Output ON voltage drop 1.8 V (RMS) max.
• Leakage current 20 mA max at 480 V ac
• Vibration resistance – destruction – 10 to 55 to 10 Hz, 0.375 mm single amplitude mounted to a DIN rail.
• Shock resistance – destruction – 300 m/s² mounted to a DIN rail.
• Operating temperature – ambient - -30°C to 80°C. No icing or condensation.
• Screw terminal.
• Relay weight 410 g.
Replacing the SSR – Solid state relay cartridge.
• Turn OFF the power supply when replacing a cartridge.
• Damaged cartridges can be replaced without disconnecting the wires.
• If the temperature indicator changes from pink to red triac circuits may be malfunctioning, replace.
• Improve heat radiation efficiency before cartridge replacement.
• Damaged cartridges can be replaced without disconnecting the wires.
• If the temperature indicator changes from pink to red triac circuits may be malfunctioning, replace.
• Improve heat radiation efficiency before cartridge replacement.
What does Zero Cross Function mean in SSR in Solid State Relays?
Zero cross function will allow the relay to turn ON when the AC load power supply approaches 0 V suppressing any noise generated with a sudden load current increase. Zero cross function is effective across 2 types of noise, noise on power lines and noise emitted into open space.
Zero Voltage Relays
Note
Temperature can affect current rating; please consult the data sheet for potential derating.
Specification
คุณสมบัติ | Value |
Maximum Load Current | 30 A |
Mounting Type | DIN Rail |
Maximum Load Voltage | 528 V ac |
Minimum Load Voltage | 180 V ac |
Minimum Control Voltage | 9.6 V dc |
Maximum Control Voltage | 30 V dc |
Switching Type | Zero Cross |
Control Voltage Range | 9.6 → 30 V dc |
Minimum Load Current | 0.5 A |
Contact Configuration | SPST |
Terminal Type | Screw |
Output Device | Phototriac Coupler |
Series | G3PA |
Load Voltage Range | 180 → 528V ac |
Maximum Turn On Time | 1/2 cycle |
Dimensions | 47 x 100 x 100mm |
Length | 47mm |
Depth | 100mm |
Operating Temperature Range | -30 → +80°C |
Off State Leakage Current | 20 mA |
Maximum Operating Temperature | +80°C |
Height | 100mm |