{"product_id":"safety-limit-switch-omron-code-d4n-2a25","title":"Limit Switch Omron D4N-2A25","description":" \u003cdiv\u003e\n   \u003ch3\u003eDimension\u003c\/h3\u003e\n   \u003cul\u003e\n     \u003cli\u003eMounting hole dimensions\u003c\/li\u003e\n   \u003c\/ul\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"image-02\"\u003e\n   \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0577\/0801\/9878\/files\/Untitled-2_59a330e6-eace-477f-b0d5-6a9e55264763.png?v=1696296455\" width=\"100%\" alt=\"รูป\"\u003e\n   \u003cdiv\u003e\n     \u003ch3\u003eCircuits configuration\u003c\/h3\u003e\n   \u003c\/div\u003e\n   \u003cdiv class=\"image-02\"\u003e\n     \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0577\/0801\/9878\/files\/E00000927464.gif?v=1696296534\" width=\"100%\" alt=\"รูป\"\u003e\n     \u003cdiv\u003e\n       \u003ch3\u003eRating \/ Performance\u003c\/h3\u003e\n       \u003ctable\u003e\n         \u003ctbody\u003e\n           \u003ctr\u003e\n             \u003ctd\u003eOperating mechanism\u003c\/td\u003e\n             \u003ctd\u003eSlow action\u003c\/td\u003e\n           \u003c\/tr\u003e\n           \u003ctr\u003e\n             \u003ctd\u003ectuator\u003c\/td\u003e\n             \u003ctd\u003eRoller lever 17.5 dia. x 7 \u003cbr\u003eMetal lever, Stainless sintered alloy rollers \u003cbr\u003eR26 \u003c\/td\u003e\n           \u003c\/tr\u003e\n           \u003ctr\u003e\n             \u003ctd\u003eFrequency\u003c\/td\u003e\n             \u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n           \u003c\/tr\u003e\n           \u003ctr\u003e\n             \u003ctd\u003eContact form\u003c\/td\u003e\n             \u003ctd\u003e1NC\/1NO\u003c\/td\u003e\n           \u003c\/tr\u003e\n           \u003ctr\u003e\n             \u003ctd\u003eLoad\u003c\/td\u003e\n             \u003ctd\u003eGeneral load\/Micro load\u003c\/td\u003e\n           \u003c\/tr\u003e\n           \u003ctr\u003e\n             \u003ctd\u003eConduit\u003c\/td\u003e\n             \u003ctd\u003eG1\/2 \u003cbr\u003eNumber of conduit: 1 \u003c\/td\u003e\n           \u003c\/tr\u003e\n           \u003ctr\u003e\n             \u003ctd\u003eAmbient temperature\u003c\/td\u003e\n             \u003ctd\u003eOperating: -30 to 70 ℃ (with no icing)\u003c\/td\u003e\n           \u003c\/tr\u003e\n           \u003ctr\u003e\n             \u003ctd\u003eAmbient humidity\u003c\/td\u003e\n             \u003ctd\u003e95% RH max.\u003c\/td\u003e\n           \u003c\/tr\u003e\n           \u003ctr\u003e\n             \u003ctd\u003ePermissible operating frequency\u003c\/td\u003e\n             \u003ctd\u003e30 operations \/ 1 minute max.\u003c\/td\u003e\n           \u003c\/tr\u003e\n           \u003ctr\u003e\n             \u003ctd\u003eContact resistance (Initial value)\u003c\/td\u003e\n             \u003ctd\u003e25 mΩ max.\u003c\/td\u003e\n           \u003c\/tr\u003e\n           \u003ctr\u003e\n             \u003ctd\u003eInsulation resistance\u003c\/td\u003e\n             \u003ctd\u003e100 MΩ min.\u003c\/td\u003e\n           \u003c\/tr\u003e\n           \u003ctr\u003e\n             \u003ctd\u003eImpulse withstand voltage\u003c\/td\u003e\n             \u003ctd\u003eBetween each terminal of the same polarities: 2.5 kV \u003cbr\u003eBetween each terminal of the different polarities: 4 kV \u003cbr\u003eBetween each terminal and non-live-metallic part: 6 kV \u003c\/td\u003e\n           \u003c\/tr\u003e\n           \u003ctr\u003e\n             \u003ctd\u003eDurability\u003c\/td\u003e\n             \u003ctd\u003eElectrical: 300,000 operations min. (10 A at 250 VAC), 500,000 operations min. (3 A at 250 VAC) \u003cbr\u003eMechanical: 15,000,000 operations min. \u003c\/td\u003e\n           \u003c\/tr\u003e\n           \u003ctr\u003e\n             \u003ctd\u003eVibration resistance\u003c\/td\u003e\n             \u003ctd\u003eMalfunction: 10 to 55 Hz, 0.75 mm single amplitude\u003c\/td\u003e\n           \u003c\/tr\u003e\n           \u003ctr\u003e\n             \u003ctd\u003eShock resistance\u003c\/td\u003e\n             \u003ctd\u003eDestruction: 1000 m\/s2 \u003cbr\u003eMalfunction: 300 m\/s2 \u003c\/td\u003e\n           \u003c\/tr\u003e\n           \u003ctr\u003e\n             \u003ctd\u003ePollution degree\u003c\/td\u003e\n             \u003ctd\u003e3 (EN60947-5-1)\u003c\/td\u003e\n           \u003c\/tr\u003e\n           \u003ctr\u003e\n             \u003ctd\u003eDegree of protection\u003c\/td\u003e\n             \u003ctd\u003eIP67\u003c\/td\u003e\n           \u003c\/tr\u003e\n           \u003ctr\u003e\n             \u003ctd\u003eClassification of protection against electric shock\u003c\/td\u003e\n             \u003ctd\u003eClass II (Double insulation)\u003c\/td\u003e\n           \u003c\/tr\u003e\n           \u003ctr\u003e\n             \u003ctd\u003eOperating Force (OF)\u003c\/td\u003e\n             \u003ctd\u003eStandard value 5 N max.\u003c\/td\u003e\n           \u003c\/tr\u003e\n           \u003ctr\u003e\n             \u003ctd\u003eRelease Force (RF)\u003c\/td\u003e\n             \u003ctd\u003eStandard value 0.5 N min.\u003c\/td\u003e\n           \u003c\/tr\u003e\n           \u003ctr\u003e\n             \u003ctd\u003ePre-Travel (PT)\u003c\/td\u003e\n             \u003ctd\u003eNC: 18 to 27 ° NO: Reference value 44 °\u003c\/td\u003e\n           \u003c\/tr\u003e\n           \u003ctr\u003e\n             \u003ctd\u003eOver-Travel (OT)\u003c\/td\u003e\n             \u003ctd\u003eStandard value 40 ° min.\u003c\/td\u003e\n           \u003c\/tr\u003e\n           \u003ctr\u003e\n             \u003ctd\u003eTotal Travel (TT)\u003c\/td\u003e\n             \u003ctd\u003eReference value 80 °\u003c\/td\u003e\n           \u003c\/tr\u003e\n           \u003ctr\u003e\n             \u003ctd\u003eDirect Opening Force\u003c\/td\u003e\n             \u003ctd\u003eStandard value 20 N min.\u003c\/td\u003e\n           \u003c\/tr\u003e\n           \u003ctr\u003e\n             \u003ctd\u003eDirect Opening Travel\u003c\/td\u003e\n             \u003ctd\u003eStandard value 50 ° min.\u003c\/td\u003e\n           \u003c\/tr\u003e\n         \u003c\/tbody\u003e\n       \u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"OMRON","offers":[{"title":"Default Title","offer_id":46160908779686,"sku":null,"price":2176.38,"currency_code":"THB","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0577\/0801\/9878\/files\/Untitled-5_095d64a3-6518-4c14-839d-44e0b6e0c093.png?v=1740632621","url":"https:\/\/northpower.co.th\/en\/products\/safety-limit-switch-omron-code-d4n-2a25","provider":"North Power","version":"1.0","type":"link"}